Valves often encounter some troublesome problems during use, such as not being tightly closed. What should be done?
In general, if the valve cannot be tightly closed, first confirm whether the valve is closed in place. If there is still leakage that cannot be sealed after it has been closed in place, then check the sealing surface. Some valves have detachable sealing pairs, so take them out for grinding and retesting. Of course, if the valve still cannot be tightly closed, it must be returned to the factory for maintenance or replaced to avoid affecting the normal use of the valve and causing accidents in working conditions.
If the valve is not tightly closed, the first step is to identify where the problem lies and then solve it according to the corresponding methods. There are several reasons why valves are generally not tightly closed:
(1) Impurities are stuck on the sealing surface, deposited at the bottom of the valve or placed between the valve disc and seat;
(2) Rust on the valve stem thread prevents the valve from rotating;
(3) The sealing surface of the valve is damaged, causing leakage of the medium;
(4) The connection between the valve stem and the valve disc is not good, causing the valve disc to deviate from the valve seat and unable to make tight contact.
The handling method for valves that are not tightly closed:
1、 Impurities are stuck on the sealing surface of the valve
Sometimes valves suddenly fail to close tightly, which may be due to impurities stuck between the sealing surfaces of the valve. At this time, do not forcefully close the valve. Instead, open the valve slightly larger and try to close it again. Repeat the process and it can generally be eliminated. Otherwise, inspection should be carried out to maintain the quality and cleanliness of the medium.
2、 Rust on valve stem threads
For valves that are usually in the open state, accidental closure may also result in loose closure due to rusted valve stem threads. For this situation, the valve can be repeatedly opened and closed several times, while tapping the bottom of the valve body with a small hammer to tightly close the valve without the need for grinding or repairing the valve.
3、 The sealing surface of the valve is damaged
For situations where the switch cannot be tightly closed after multiple attempts, it indicates that the sealing surface is damaged and should be reported for repair; Or if the sealing surface is damaged by corrosion, particle scratches in the medium, etc., it should also be reported for repair.
4、 Poor connection between valve stem and valve disc
Regularly lubricate the valve stem and stem nut to ensure the flexibility of valve opening and closing. We need a formal maintenance plan.