I. Causes and troubleshooting methods for leakage in valve body and cover:
(I) Causes of malfunctions:
- Poor casting quality of cast iron parts, with defects such as sand holes, loose structure, and slag inclusions on the valve body and cover;
- Freezing cracking due to weathering;
- Poor welding, with defects such as slag inclusions, incomplete welding, and stress cracks;
- Damage to cast iron copper valves after impact with heavy objects.
(II) Troubleshooting Methods:
- Improve casting quality; strictly conduct strength tests according to regulations before installation;
- For copper valves with temperatures at or below 0°C, insulation or heating should be provided. Water should be drained from copper valves that are no longer in use;
- Welds in valve bodies and covers composed of welded components should be performed according to relevant welding operation procedures. Flaw detection and strength tests should also be conducted after welding;
- Heavy objects should not be placed on copper valves. Hammering cast iron and non-metallic copper valves is prohibited. Large-diameter copper valves should be installed with supports.
II. Causes and Troubleshooting Methods for Leakage at the Packing Section:
(I) Causes of Leakage: (External leakage in copper valves is most prevalent at the packing section)
- Incorrect packing selection; not resistant to media corrosion, and not resistant to high pressure, vacuum, high temperature, or low temperature operation of copper valves;
- Incorrect packing installation; defects such as using smaller packing for larger ones, poor spiral winding joints, and packing that is too tight at the top and too loose at the bottom;
- Packing exceeding its service life; aged and lost elasticity;
- 5. Insufficient packing rings, gland not tightened;
- Damage to gland, bolts, and other components, preventing gland tightening;
- Improper operation, excessive force, etc.;
- Gland misalignment, gap between gland and valve stem too small or too large, causing valve stem wear and packing damage.
(II) Troubleshooting Methods:
- Select packing material and type according to operating conditions;
- Install packing correctly according to relevant regulations. Packing rings should be installed and tightened one by one, and joints should be at 30° or 45°;
- Replace packing that has been used for too long, is aged, or damaged in a timely manner;
- Straighten and repair valve stems that are bent or worn. Replace severely damaged stems promptly;
- Packing should be installed according to the specified number of rings. Gland should be tightened symmetrically and evenly, and the gland should have a pre-tightening gap of at least 5mm;
- Damaged glands, bolts, and other components should be repaired or replaced promptly;
- Operating procedures should be followed, and except for impact-type handwheels, operation should be performed with uniform speed and normal force;
- The gland bolts should be tightened evenly and symmetrically. If the gap between the gland and the valve stem is too small, the gap should be increased appropriately. If the gap between the gland and the valve stem is too large, it should be replaced.
III. Causes and troubleshooting methods for leakage at the sealing surface:
(I) Causes of the fault:
- The sealing surface is not ground evenly, failing to form a tight seal.
- The valve stem and the closing element are not properly aligned, the valve core is not aligned, or it is worn.
- The valve stem is bent or improperly assembled, causing the closing element to be skewed or misaligned.
- The sealing material is not properly selected or the valve is not selected according to the operating conditions.
(II) Troubleshooting methods:
- Select the correct material and type of gasket according to the operating conditions.
- Adjust carefully and operate smoothly.
- Tighten the bolts evenly and symmetrically. If necessary, use a torque wrench. The pre-tightening force should meet the requirements and should not be too large or too small. 4. Flanges and threaded connections should have a certain pre-tightening clearance;
- Gaskets should be aligned and evenly stressed during assembly. Overlapping gaskets and the use of double gaskets are not permitted;
- Corrosion, damage, or poor processing quality of the static sealing surface should be repaired, ground, and subjected to colorimetric testing to ensure the static sealing surface meets relevant requirements;
- Cleanliness should be maintained during gasket installation. The sealing surface should be cleaned with kerosene, and gaskets should not be allowed to touch the ground.
IV. Causes and Troubleshooting of Leakage at Sealing Ring Connections:
(I) Causes of Leakage:
- Inadequate sealing ring compaction;
- Poor welding quality between the sealing ring and the body;
- Loose threads, screws, or pressure rings connecting the sealing ring;
- Corrosion of the sealing ring connection.
(II) Troubleshooting Methods:
- For leaks at the sealing compaction point, apply adhesive and then compact again for fixation;
- The sealing ring should be re-welded according to the welding specifications without disassembly. 3. When weld overlays cannot be repaired, the original weld overlay and machining should be removed;
- Remove screws and pressure rings, clean them, replace damaged parts, grind the sealing and connecting seat mating surfaces, and reassemble. For parts with significant corrosion damage, welding or bonding methods can be used for repair;
- If the sealing ring connection surface is corroded, it can be repaired by grinding or bonding. If repair is not possible, the sealing ring should be replaced.
- Causes and troubleshooting methods for leakage caused by detached closing parts:
(I) Causes of the fault:
- Improper operation, causing the closing part to jam or exceed the top dead point, resulting in damage or breakage at the connection;
- The closing part is not securely connected, becoming loose and detaching;
- The material of the connecting parts is inappropriate and cannot withstand the corrosion of the medium and mechanical wear. (II) Troubleshooting Methods:
- Operate correctly: Do not use excessive force to close the copper valve; do not open the copper valve beyond the top dead center; after the copper valve is fully open, the handwheel should be turned back slightly;
- The connection between the closing element and the valve stem should be secure, and the threaded connection should have a locking device;
- The fasteners used to connect the closing element and the valve stem should withstand the corrosion of the medium and have a certain mechanical strength and wear resistance.